3000 tr/min 50 Hz – cos ϕ 0,8 230V – 400/230V 3600 tr/min 60 Hz – cos ϕ 0,8 voltage sous demande

BX LIGHTING TOWER

 EQUIPEMENT STANDARD

• Groupes électrogènes série LX ou SX

• Mât pneumatique (hauteur max 5,5mt)

• 4 lampes halogènes de 500W chacune

• Remorque avec roues pneumatiquespour déplacements manuels

• 4 pieds stabilisants individuellement réglables

• Câble de connection entre lampes et groupe électrogène

ESSENCE ET DIESEL Refroidis par air

BX LIGHTING TOWER

3000-3600 MODEL50 Hz kVA max60 Hz kVA max60 Hz kVA contStartingBrandEngineCylindercm3Hp (max) 3600Cons. 75%(h/l)LWAtankLW H KgH MAX CMLUMEN TOTStandard panel

MODEL

kVA max

kVA cont

kVA max

kVA cont

Starting

Brand

Cylinder

cm3

Hp (max) 3600

Cons. 75%(h/l)

LWA

H MAX CM

LUMEN TOT

Standard panel

50 Hz

60 Hz

Engine Technical Data

Tank l

L

W

H

Kg

PETROL GENERATORS

SINGLE-PHASE

BXP5000-DY4.54.15.45MHondaGX270127091.595201048218011355040000QM105
BXP5000E-DY4.54.15.45EHondaGX270127091.595201048218012055040000QM105
BXP8000-DY7.26.587.2MHondaGX3901389131.996201048218012455040000QM105
BXP8000E-DY7.26.587.2EHondaGX3901389131.996201048218013155040000QM105

THREE-PHASE

BXP6500T-DY5.44.96.55.6MHondaGX270127091.595201048218012355040000QM305
BXP8000T-DY 7.56.88.37.5MHondaGX3901389131.996201048218012955040000QM305
BXP8000TE-DY7.56.88.37.5EHondaGX3901389131.996201048218013655040000QM305
DIESEL GENERATORS

SINGLE-PHASE

BXD5000-DY4.64.25.14.7MKohler15LD35013497.51.2>100201048218012655040000QM106
BXD5000E-DY4.64.25.14.7EKohler15LD35013497.51.2>100201048218013355040000QM106
BXD7500-DY76.47.56.8MKohler15LD4401442111.6>100201048218014555040000QM106
BXD7500E-DY76.47.56.8EKohler15LD4401442111.6>100201048218015155040000QM106

THREE-PHASE

BXD7500T-DY7.36.67.56.8MKohler15LD4401442111.6>100201048218015055040000QM306
BXD7500TE-DY7.36.67.56.8EKohler15LD4401442111.6>100201048218015755040000QM306

Légende: (•) = Valeur mesurée, Niveau de bruit conforme à la réglementation 2000/14/CE

> COFFRET DE COMMANDE